• 1/4

YAlkaid

Yalkaid 100KHz Full-Range SS-OCT

T100KHz speed full-range swept-source OCT for anterior and posterior. An ideal choice for comprehensive OCT application with only one device.
产品详情技术参数

Features:

Yalkaid (YG-100K) features a new generation SS-OCT with a remarkable speed of 100kHz. Its key advantage lies in the full-range SS technology, enabling a scan depth of 12 mm for the vitreous, retina, choroid, and an extraordinary 15 mm for the anterior. The device's <6 micron optical resolution ensures detailed observation of both anterior and posterior structures.

With a wavelength of 1060 nm, Yalkaid is particularly beneficial for scanning patients with cataracts and vitreous opacities. Its invisible character minimizes fixation distractions. Moreover, its extensive 17 mm line scans and 15 mm 3D/OCTA scans cover a larger area comparedtotraditional SD or SS-OCTs.

Yalkaid is equipped with a wide range of quantification and analysis tools that greatly assist in clinical practice and research. These features enhance diagnostic precision and contributetobetter patient outcomes.


OCT Model: YG-100K

OCT optical sourceSwept Source
Center wavelength1060nm
OCT B - scan
Scan speed100,000 A - scans/sec
Max. Length (posterior)17mm
Max. Length (anterior)24mm
Scan depth (posterior)12mm
Scan depth (anterior)15mm
Refractive adjustment range- 20D to +15D
Axial optical resolution≤6μm
Transverse optical resolution10μm
Fundus Imaging
MethodologyLine - scanning ophthalmoscope (LSO)
LSO wavelength850nm
LSO FOV40°×40°
Minimum pupil diameter2.0mm
Eye tracking speed60Hz
OCT Angiography
Max. Single scan size (anterior)18mm×18mm
Max. Single scan size (posterior)15mm×15mm
Maximum resolution (single scan)1024×1024
Software Functions
Anterior segment (AS) quantification
AS panoramic parameters
Thickness/volume measurement (retina)
Thickness/volume measurement (choroid)
Glaucoma analysis (GMA, ONH, etc.)
Blood flow quantification (retina)
Blood flow quantification (choroid)
Blood flow quantification (optic disk)
Blood flow quantification (AS)
Posterior curvature
3D Structure
3D vessel


Clinical atlas
  • 12×12 mm OCTA
    12×12 mm OCTA
  • Diabetic retinopathy (12×12mm OCTA)
    Diabetic retinopathy (12×12mm OCTA)
  • Panoramic anterior segment - cataract
    Panoramic anterior segment - cataract
  • Panoramic front section -ICL
    Panoramic front section -ICL
  • High myopia (16mm lateral, 6mm deep)
    High myopia (16mm lateral, 6mm deep)
  • Extensive retinal detachment
    Extensive retinal detachment
  • Intraocular lens and anterior vitreous body
    Intraocular lens and anterior vitreous body
  • Intraocular lens
    Intraocular lens
  • ICL
    ICL
  • Posterior vitreous detachment
    Posterior vitreous detachment
  • Retinal detachment with yellow pan hole
    Retinal detachment with yellow pan hole
  • Posterior vitreous detachment
    Posterior vitreous detachment
  • Anterior pouch of posterior vitreous cortex
    Anterior pouch of posterior vitreous cortex
123...5